Wellea Monobloc

Compact heat pump, can be installed
outside and kept out of sight

Wellea monobloc

Wellea Monobloc

Heating/Cooling
Hot water

Monobloc heat pump

Ref. WHPM

The Wellea Monobloc heat pump is an all-in-one home solution that manages hot water, heating and cooling. With a single outdoor unit, Wellea Monoloc can be easily integrated wherever you need it and can be adapted to every transmitter in your home: underfloor heating, radiators or fan convectors.

A+++

Monobloc version

monobloc
Ideal for replacing oil or gas boilers
High energy rating A+++
High flexibility of use
Operation down to -25°C and +46°C outside

Don’t put up with peaks
of temperature any more

Designed for outdoor temperatures ranging from -25°C to 46°C, the Wellea Monobloc heat pump provides rapid temperature control. It guarantees a constant and comfortable environment in both winter and summer.

Compatible with all
your equipment

The Wellea Monobloc heat pump is compatible with all transmitters and can be used with underfloor heating, radiators or fan coil units.

A+++ energy rating,
economy and ecology

Wellea heat pumps have an A++ energy rating, the highest rating there is. Reduce your energy bill compared to a boiler or standard electric radiators.

Easy to install

Installing a Wellea Monobloc heat pump is quick because not much fixing work is required. It is the ideal solution for those who want comfort quickly without extensive fixing work.

Remote control

With Wi-Fi connectivity, you can control the temperature of your home from anywhere. The AirHome smartphone application lets you control the thermostat remotely for a perfect temperature as soon as you arrive or a stop if you’re away.

Your Airwell package

Outdoor unit and remote control

monobloc

Find the version that suits you

Reference

Ref. Outdoor unit:

AW-WHPMA04-H91

Refrigerator/PRP:

R32/675

Cooling

Power (A35/W18) :

4,5 kW

EER (A35/W18) :

5,5

ηsc

307 %

Heating

Power (A7/W35) :

4,2

COP (A7/W35) :

5,1 kW

ηsh/Energy class :

191%/A+++

Outdoor unit

Sound pressure at 1 m:

45 dB (A)

Acoustic power:

55 dB (A)

Unit dimensions (WxHxD):

1295x792x429 mm

Net weight:

98 kg

Power supply

Phase/Voltage/Frequency:

1P/220-240V/50Hz

Phase :

Single-phase

Reference

Ref. Outdoor unit:

AW-WHPMA06-H91

Refrigerator/PRP:

R32/675

Cooling

Power (A35/W18) :

6,5 kW

EER (A35/W18) :

4,8

ηsc

325 %

Heating

Power (A7/W35) :

6,35 kW

COP (A7/W35) :

4,95

ηsh/Energy class :

195%/A+++

Outdoor unit

Sound pressure at 1 m:

48 dB (A)

Acoustic power:

58 dB (A)

Unit dimensions (WxHxD):

1295x792x429 mm

Net weight:

98 kg

Power supply

Phase/Voltage/Frequency:

1P/220-240V/50Hz

Phase :

Single-phase

Reference

Ref. Outdoor unit:

AW-WHPMA08-H91

Refrigerator/PRP:

R32/675

Cooling

Power (A35/W18) :

8,3 kW

EER (A35/W18) :

5,05

ηsc

355 %

Heating

Power (A7/W35) :

8,4 kW

COP (A7/W35) :

5,15

ηsh/Energy class :

205%/A+++

Outdoor unit

Sound pressure at 1 m:

49 dB (A)

Acoustic power:

59 dB (A)

Unit dimensions (WxHxD):

1385x945x526 mm

Net weight:

121 kg

Power supply

Phase/Voltage/Frequency:

1P/220-240V/50Hz

Phase :

Single-phase

Reference

Ref. Outdoor unit:

AW-WHPMA10-H91

Refrigerator/PRP:

R32/675

Cooling

Power (A35/W18) :

9,9 kW

EER (A35/W18) :

4,55

ηsc

348 %

Heating

Power (A7/W35) :

10 kW

COP (A7/W35) :

4,95

ηsh/Energy class :

205%/A+++

Outdoor unit

Sound pressure at 1 m:

51 dB (A)

Acoustic power:

60 dB (A)

Unit dimensions (WxHxD):

1385x945x526 mm

Net weight:

121 kg

Power supply

Phase/Voltage/Frequency:

1P/220-240V/50Hz

Phase :

Single-phase

Reference

Ref. Outdoor unit:

AW-WHPMA12-H91

Refrigerator/PRP:

R32/675

Cooling

Power (A35/W18) :

12 kW

EER (A35/W18) :

3,95

ηsc

280 %

Heating

Power (A7/W35) :

12,1 kW

COP (A7/W35) :

4,95

ηsh/Energy class :

189%/A+++

Outdoor unit

Sound pressure at 1 m:

53 dB (A)

Acoustic power:

65 dB (A)

Unit dimensions (WxHxD):

1385x945x526 mm

Net weight:

144 kg

Power supply

Phase/Voltage/Frequency:

1P/220-240V/50Hz

Phase :

Single-phase

Reference

Ref. Outdoor unit:

AW-WHPMA12-H93

Refrigerator/PRP:

R32/675

Cooling

Power (A35/W18) :

12 kW

EER (A35/W18) :

3,95

ηsc

280 %

Heating

Power (A7/W35) :

12,1 kW

COP (A7/W35) :

4,95

ηsh/Energy class :

189%/A+++

Outdoor unit

Sound pressure at 1 m:

53 dB (A)

Acoustic power:

65 dB (A)

Unit dimensions (WxHxD):

1385x945x526 mm

Net weight:

160 kg

Power supply

Phase/Voltage/Frequency:

3P/380-415V/50Hz

Phase :

Triple phase

Reference

Ref. Outdoor unit:

AW-WHPMA14-H91

Refrigerator/PRP:

R32/675

Cooling

Power (A35/W18) :

13,5 kW

EER (A35/W18) :

3,6

ηsc

272 %

Heating

Power (A7/W35) :

14,5 kW

COP (A7/W35) :

4,6

ηsh/Energy class :

186%/A+++

Outdoor unit

Sound pressure at 1 m:

54 dB (A)

Acoustic power:

65 dB (A)

Unit dimensions (WxHxD):

1385x945x526 mm

Net weight:

144 kg

Power supply

Phase/Voltage/Frequency:

1P/220-240V/50Hz

Phase :

Single-phase

Reference

Ref. Outdoor unit:

AW-WHPMA14-H93

Refrigerator/PRP:

R32/675

Cooling

Power (A35/W18) :

13,5 kW

EER (A35/W18) :

3,6

ηsc

272 %

Heating

Power (A7/W35) :

14,5 kW

COP (A7/W35) :

4,6

ηsh/Energy class :

186%/A+++

Outdoor unit

Sound pressure at 1 m:

54 dB (A)

Acoustic power:

65 dB (A)

Unit dimensions (WxHxD):

1385x945x526 mm

Net weight:

160 kg

Power supply

Phase/Voltage/Frequency:

3P/380-415V/50Hz

Phase :

Triple phase

Reference

Ref. Outdoor unit:

AW-WHPMA16-H91

Refrigerator/PRP:

R32/675

Cooling

Power (A35/W18) :

14,9 kW

EER (A35/W18) :

3,4

ηsc

266 %

Heating

Power (A7/W35) :

15,9 kW

COP (A7/W35) :

4,5

ηsh/Energy class :

182%/A+++

Outdoor unit

Sound pressure at 1 m:

58 dB (A)

Acoustic power:

68 dB (A)

Unit dimensions (WxHxD):

1385x945x526 mm

Net weight:

144 kg

Power supply

Phase/Voltage/Frequency:

1P/220-240V/50Hz

Phase :

Single-phase

Reference

Ref. Outdoor unit:

AW-WHPMA16-H93

Refrigerator/PRP:

R32/675

Cooling

Power (A35/W18) :

14,9 kW

EER (A35/W18) :

3,4

ηsc

266 %

Heating

Power (A7/W35) :

15,9 kW

COP (A7/W35) :

4,5

ηsh/Energy class :

182%/A+++

Outdoor unit

Sound pressure at 1 m:

58 dB (A)

Acoustic power:

68 dB (A)

Unit dimensions (WxHxD):

1385x945x526 mm

Net weight:

160 kg

Power supply

Phase/Voltage/Frequency:

3P/380-415V/50Hz

Phase :

Triple phase