Wellzone
Reversible air conditioning
Built-in range
Ref. DDM / Wellzone
The Wellzone reversible air-conditioning system can be installed in a false ceiling and thus be hidden completely from view. You enjoy the luxury of an invisible solution for your home and can set the right temperature room by room for optimum comfort.
Customisable thermostat,
each room has its own temperature
Our customisation system provides individual heating management for each room, up to 6 zones. Everyone can manage their temperature in the room that matters most to them.
As invisible as it is
silent
This air conditioner can be installed in a false ceiling for perfect integration. This invisible and silent solution is unrivalled in its discretion.
Define your routines.
Wellzone adapts to it
To adapt to all lifestyles, the Wellzone reversible air conditioning system can be programmed on a weekly basis. Once you have set up your routines, the device will activate them automatically, without you even having to think about it.
Find the version that suits you
- 3,5 kW / 12 kBTU
- 5,3 kW / 18 kBTU
- 7 kW / 24 kBTU
- 10,5 kW / 36 kBTU
- 10,5 kW / 36 kBTU
- 14 kW / 48 kBTU
- 15,2 kW / 60 kBTU
Reference
Ref. Indoor unit:
AW-DDM012-N91
Ref. Outdoor unit:
AW-YDFA012-H91
Cooling
Refrigerator/PRP:
R32/675
Rated power (min./max):
3,53 (1,50-4,75) kW
SEER/Energy class:
6,5/A++
Heating
Rated power (min./max):
4,10 (0,97-5,63) kW
SCOP/Energy class (temperate climate):
4/A+
Indoor unit
Sound pressure at 1 m (TPV/PV/MV/GV):
26/31/35 dB (A)
Acoustic power:
56 dB (A)
Unit dimensions (WxHxD):
700x200x506 mm
Net weight:
18 kg
Outdoor unit
Sound pressure at 1 m:
56 dB (A)
Acoustic power:
62 dB (A)
Unit dimensions (WxHxD):
800x554x333 mm
Net weight:
34,7 kg
Power supply
Phase/Voltage/Frequency:
1P/220-240V/50Hz
Phase :
Single-phase
Reference
Ref. Indoor unit:
AW-DDM018-N91
Ref. Outdoor unit:
AW-YDFA018-H91
Cooling
Refrigerator/PRP:
R32/675
Rated power (min./max):
5,30 (1,49-5,69) kW
SEER/Energy class:
6,1/A++
Heating
Rated power (min./max):
5,84 (2,2-6,15) kW
SCOP/Energy class (temperate climate):
4/A+
Indoor unit
Sound pressure at 1 m (TPV/PV/MV/GV):
33/38/42 dB (A)
Acoustic power:
59 dB (A)
Unit dimensions (WxHxD):
880x210x674 mm
Net weight:
24,3 kg
Outdoor unit
Sound pressure at 1 m:
55 dB (A)
Acoustic power:
62 dB (A)
Unit dimensions (WxHxD):
800x554x333 mm
Net weight:
33,7 kg
Power supply
Phase/Voltage/Frequency:
1P/220-240V/50Hz
Phase :
Single-phase
Reference
Ref. Indoor unit:
AW-DDM024-N91
Ref. Outdoor unit:
AW-YDFA024-H91
Cooling
Refrigerator/PRP:
R32/675
Rated power (min./max):
7,05 (3,28-8,16) kW
SEER/Energy class:
6,1/A++
Heating
Rated power (min./max):
7,60 (2,72-8,72) kW
SCOP/Energy class (temperate climate):
4/A+
Indoor unit
Sound pressure at 1 m (TPV/PV/MV/GV):
38/40/42 dB (A)
Acoustic power:
62 dB (A)
Unit dimensions (WxHxD):
1100x249x774 mm
Net weight:
31,5 kg
Outdoor unit
Sound pressure at 1 m:
61 dB (A)
Acoustic power:
66 dB (A)
Unit dimensions (WxHxD):
845x702x363 mm
Net weight:
49,4 kg
Power supply
Phase/Voltage/Frequency:
1P/220-240V/50Hz
Phase :
Single-phase
Reference
Ref. Indoor unit:
AW-DDM036-N91
Ref. Outdoor unit:
AW-YDFA036-H91
Cooling
Refrigerator/PRP:
R32/675
Rated power (min./max):
10,50 (4,04-12,02) kW
SEER/Energy class:
6,1/A++
Heating
Rated power (min./max):
11,10 (2,81-13,19) kW
SCOP/Energy class (temperate climate):
4/A+
Indoor unit
Sound pressure at 1 m (TPV/PV/MV/GV):
39/42/45 dB (A)
Acoustic power:
62 dB (A)
Unit dimensions (WxHxD):
1360x249x774 mm
Net weight:
40,5 kg
Outdoor unit
Sound pressure at 1 m:
63 dB (A)
Acoustic power:
68 dB (A)
Unit dimensions (WxHxD):
946x810x410 mm
Net weight:
66,8 kg
Power supply
Phase/Voltage/Frequency:
1P/220-240V/50Hz
Phase :
Single-phase
Reference
Ref. Indoor unit:
AW-DDM036-N91
Ref. Outdoor unit:
AW-YDFA036-H93
Cooling
Refrigerator/PRP:
R32/675
Rated power (min./max):
10,50 (4,04-12,02) kW
SEER/Energy class:
6,1/A++
Heating
Rated power (min./max):
11,10 (2,81-13,19) kW
SCOP/Energy class (temperate climate):
4/A+
Indoor unit
Sound pressure at 1 m (TPV/PV/MV/GV):
40/43/50 dB (A)
Acoustic power:
63 dB (A)
Unit dimensions (WxHxD):
1360x249x774 mm
Net weight:
40,5 kg
Outdoor unit
Sound pressure at 1 m:
64 dB (A)
Acoustic power:
68 dB (A)
Unit dimensions (WxHxD):
946x810x410 mm
Net weight:
81,5 kg
Power supply
Phase/Voltage/Frequency:
3P/380-410V/50Hz
Phase :
Triple phase
Reference
Ref. Indoor unit:
AW-DDM048-N91
Ref. Outdoor unit:
AW-YDFA048-H93
Cooling
Refrigerator/PRP:
R32/675
Rated power (min./max):
14,18 (4,26-15,19) kW
SEER/Energy class:
6,1/A++
Heating
Rated power (min./max):
15,70 (3,7-18,02) kW
SCOP/Energy class (temperate climate):
4/A+
Indoor unit
Sound pressure at 1 m (TPV/PV/MV/GV):
48/50/51 dB (A)
Acoustic power:
68 dB (A)
Unit dimensions (WxHxD):
1200x300x874 mm
Net weight:
47,6 kg
Outdoor unit
Sound pressure at 1 m:
66 dB (A)
Acoustic power:
72 dB (A)
Unit dimensions (WxHxD):
952x1333x415 mm
Net weight:
106,7 kg
Power supply
Phase/Voltage/Frequency:
3P/380-410V/50Hz
Phase :
Triple phase
Reference
Ref. Indoor unit:
AW-DDM060-N91
Ref. Outdoor unit:
AW-YDFA060-H93
Cooling
Refrigerator/PRP:
R32/675
Rated power (min./max):
15,24 (5,86-17,29) kW
SEER/Energy class:
6,1/A++
Heating
Rated power (min./max):
18,17 (4,69-20,52) kW
SCOP/Energy class (temperate climate):
4/A+
Indoor unit
Sound pressure at 1 m (TPV/PV/MV/GV):
51/52/54 dB (A)
Acoustic power:
71 dB (A)
Unit dimensions (WxHxD):
1200x300x874 mm
Net weight:
47,6 kg
Outdoor unit
Sound pressure at 1 m:
64 dB (A)
Acoustic power:
74 dB (A)
Unit dimensions (WxHxD):
952x1333x415 mm
Net weight:
111,3 kg
Power supply
Phase/Voltage/Frequency:
3P/380-410V/50Hz
Phase :
Triple phase