Wellzone

The comfort of invisibility,
to each room its temperature

Wellzone

Wellzone

Reversible air conditioning

Built-in range

Ref. DDM / Wellzone

The Wellzone reversible air-conditioning system can be installed in a false ceiling and thus be hidden completely from view. You enjoy the luxury of an invisible solution for your home and can set the right temperature room by room for optimum comfort.

Customisable thermostat,
each room has its own temperature

Our customisation system provides individual heating management for each room, up to 6 zones. Everyone can manage their temperature in the room that matters most to them.

wellzone schema

As invisible as it is
silent

This air conditioner can be installed in a false ceiling for perfect integration. This invisible and silent solution is unrivalled in its discretion.

Define your routines.
Wellzone adapts to it

To adapt to all lifestyles, the Wellzone reversible air conditioning system can be programmed on a weekly basis. Once you have set up your routines, the device will activate them automatically, without you even having to think about it.

Your Airwell package

Indoor unit, plenum, thermostats and outdoor unit

pack wellzone

Find the version that suits you

Reference

Ref. Indoor unit:

AW-DDM012-N91

Ref. Outdoor unit:

AW-YDFA012-H91

Cooling

Refrigerator/PRP:

R32/675

Rated power (min./max):

3,53 (1,50-4,75) kW

SEER/Energy class:

6,5/A++

Heating

Rated power (min./max):

4,10 (0,97-5,63) kW

SCOP/Energy class (temperate climate):

4/A+

Indoor unit

Sound pressure at 1 m (TPV/PV/MV/GV):

26/31/35 dB (A)

Acoustic power:

56 dB (A)

Unit dimensions (WxHxD):

700x200x506 mm

Net weight:

18 kg

Outdoor unit

Sound pressure at 1 m:

56 dB (A)

Acoustic power:

62 dB (A)

Unit dimensions (WxHxD):

800x554x333 mm

Net weight:

34,7 kg

Power supply

Phase/Voltage/Frequency:

1P/220-240V/50Hz

Phase :

Single-phase

Reference

Ref. Indoor unit:

AW-DDM018-N91

Ref. Outdoor unit:

AW-YDFA018-H91

Cooling

Refrigerator/PRP:

R32/675

Rated power (min./max):

5,30 (1,49-5,69) kW

SEER/Energy class:

6,1/A++

Heating

Rated power (min./max):

5,84 (2,2-6,15) kW

SCOP/Energy class (temperate climate):

4/A+

Indoor unit

Sound pressure at 1 m (TPV/PV/MV/GV):

33/38/42 dB (A)

Acoustic power:

59 dB (A)

Unit dimensions (WxHxD):

880x210x674 mm

Net weight:

24,3 kg

Outdoor unit

Sound pressure at 1 m:

55 dB (A)

Acoustic power:

62 dB (A)

Unit dimensions (WxHxD):

800x554x333 mm

Net weight:

33,7 kg

Power supply

Phase/Voltage/Frequency:

1P/220-240V/50Hz

Phase :

Single-phase

Reference

Ref. Indoor unit:

AW-DDM024-N91

Ref. Outdoor unit:

AW-YDFA024-H91

Cooling

Refrigerator/PRP:

R32/675

Rated power (min./max):

7,05 (3,28-8,16) kW

SEER/Energy class:

6,1/A++

Heating

Rated power (min./max):

7,60 (2,72-8,72) kW

SCOP/Energy class (temperate climate):

4/A+

Indoor unit

Sound pressure at 1 m (TPV/PV/MV/GV):

38/40/42 dB (A)

Acoustic power:

62 dB (A)

Unit dimensions (WxHxD):

1100x249x774 mm

Net weight:

31,5 kg

Outdoor unit

Sound pressure at 1 m:

61 dB (A)

Acoustic power:

66 dB (A)

Unit dimensions (WxHxD):

845x702x363 mm

Net weight:

49,4 kg

Power supply

Phase/Voltage/Frequency:

1P/220-240V/50Hz

Phase :

Single-phase

Reference

Ref. Indoor unit:

AW-DDM036-N91

Ref. Outdoor unit:

AW-YDFA036-H91

Cooling

Refrigerator/PRP:

R32/675

Rated power (min./max):

10,50 (4,04-12,02) kW

SEER/Energy class:

6,1/A++

Heating

Rated power (min./max):

11,10 (2,81-13,19) kW

SCOP/Energy class (temperate climate):

4/A+

Indoor unit

Sound pressure at 1 m (TPV/PV/MV/GV):

39/42/45 dB (A)

Acoustic power:

62 dB (A)

Unit dimensions (WxHxD):

1360x249x774 mm

Net weight:

40,5 kg

Outdoor unit

Sound pressure at 1 m:

63 dB (A)

Acoustic power:

68 dB (A)

Unit dimensions (WxHxD):

946x810x410 mm

Net weight:

66,8 kg

Power supply

Phase/Voltage/Frequency:

1P/220-240V/50Hz

Phase :

Single-phase

Reference

Ref. Indoor unit:

AW-DDM036-N91

Ref. Outdoor unit:

AW-YDFA036-H93

Cooling

Refrigerator/PRP:

R32/675

Rated power (min./max):

10,50 (4,04-12,02) kW

SEER/Energy class:

6,1/A++

Heating

Rated power (min./max):

11,10 (2,81-13,19) kW

SCOP/Energy class (temperate climate):

4/A+

Indoor unit

Sound pressure at 1 m (TPV/PV/MV/GV):

40/43/50 dB (A)

Acoustic power:

63 dB (A)

Unit dimensions (WxHxD):

1360x249x774 mm

Net weight:

40,5 kg

Outdoor unit

Sound pressure at 1 m:

64 dB (A)

Acoustic power:

68 dB (A)

Unit dimensions (WxHxD):

946x810x410 mm

Net weight:

81,5 kg

Power supply

Phase/Voltage/Frequency:

3P/380-410V/50Hz

Phase :

Triple phase

Reference

Ref. Indoor unit:

AW-DDM048-N91

Ref. Outdoor unit:

AW-YDFA048-H93

Cooling

Refrigerator/PRP:

R32/675

Rated power (min./max):

14,18 (4,26-15,19) kW

SEER/Energy class:

6,1/A++

Heating

Rated power (min./max):

15,70 (3,7-18,02) kW

SCOP/Energy class (temperate climate):

4/A+

Indoor unit

Sound pressure at 1 m (TPV/PV/MV/GV):

48/50/51 dB (A)

Acoustic power:

68 dB (A)

Unit dimensions (WxHxD):

1200x300x874 mm

Net weight:

47,6 kg

Outdoor unit

Sound pressure at 1 m:

66 dB (A)

Acoustic power:

72 dB (A)

Unit dimensions (WxHxD):

952x1333x415 mm

Net weight:

106,7 kg

Power supply

Phase/Voltage/Frequency:

3P/380-410V/50Hz

Phase :

Triple phase

Reference

Ref. Indoor unit:

AW-DDM060-N91

Ref. Outdoor unit:

AW-YDFA060-H93

Cooling

Refrigerator/PRP:

R32/675

Rated power (min./max):

15,24 (5,86-17,29) kW

SEER/Energy class:

6,1/A++

Heating

Rated power (min./max):

18,17 (4,69-20,52) kW

SCOP/Energy class (temperate climate):

4/A+

Indoor unit

Sound pressure at 1 m (TPV/PV/MV/GV):

51/52/54 dB (A)

Acoustic power:

71 dB (A)

Unit dimensions (WxHxD):

1200x300x874 mm

Net weight:

47,6 kg

Outdoor unit

Sound pressure at 1 m:

64 dB (A)

Acoustic power:

74 dB (A)

Unit dimensions (WxHxD):

952x1333x415 mm

Net weight:

111,3 kg

Power supply

Phase/Voltage/Frequency:

3P/380-410V/50Hz

Phase :

Triple phase